[Evaluation of the Distribution of Spatial Scattered Radiation Dose in Bedside Dynamic Chest Radiography]
Kazuki Otomo1, Tomoyoshi Kawabata1, Syu Onodera1
1Department of Radiology Division of Medical Technology, Tohoku University Hospital.
Purpose:
The purpose of this study was to determine the distribution of spatial scattered radiation during mobile dynamic chest radiography and to develop protective measures.
Methods:
We measured the spatial scattered radiation, assuming both mobile chest radiography and mobile dynamic chest radiography. We placed the chest phantom on a stretcher. Gatch-up angles were varied from 75°(seated position), 35°(semi-seated position), and 0°(supine position). We measured spatial scattered radiation using the ionization chamber survey meter. The height of the measurement points was 100 cm and 150 cm, assuming the position of the abdomen and lens. We also measured spatial scattered radiation using the radiation shielding screen.
Results:
Spatial scattered radiation dose in mobile dynamic chest radiography was approximately five to six times higher than in mobile chest radiography. In the seated position, the spatial scattered radiation dose was about 1.5 times higher on the caudal side of the phantom compared to the cranial side. Behind the radiation shielding screen, the spatial scattered radiation dose decreased significantly.
Conclusion:
If the examination is performed in a seated position, the radiological technologist can reduce exposure by moving to the patient's head side. Radiation shielding screens are very effective in reducing radiation exposure in mobile dynamic chest radiography.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
X-ray Imaging