Related Experiment Video
Updated: Jun 5, 2025

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Evaluation of leg symmetry in muscle oxygen saturation during submaximal to maximal cycling exercise
Carlos Sendra-Pérez1,2, Jose I Priego-Quesada1,3,4, Juan M Murias5
1Department of Physical Education and Sports, Research Group in Sports Biomechanics (GIBD), Universitat de València, Valencia, Spain.
Abstract:
It is unclear whether physiological responses, such as muscle oxygen saturation (SmO2), can be considered symmetrical during cycling. This knowledge has important practical implications for both training and performance assessment. The aim of this study was to determine whether oxygenation profiles in the three active muscles of both legs were symmetrical during cycling at different intensities. Twenty-six trained cyclists and triathletes completed a graded exercise test (GXT) and an 8-min functional threshold power estimation test (8MTT) on a cycle ergometer over two nonconsecutive days. SmO2 was bilaterally assessed using NIRS technology in the vastus lateralis, gastrocnemius medialis, and tibialis anterior. Symmetry was compared between legs in both tests, and reliability and agreement between the measurements were quantified. The main results were that SmO2 in the three muscles assessed did not differ between legs during the GXT and 8MTT (p > 0.05). Reliability of the measures was poor to good in the vastus lateralis (ICC = 0.83-0.37), moderate to excellent in the tibialis anterior (ICC = 0.92-0.73), and poor to good for the gastrocnemius medialis (ICC = 0.80-0.24). Overall, the group variability in SmO2 showed a narrower distribution at lower intensities, with data dispersion increasing at higher intensities. In conclusion, the SmO2 was similar and showed symmetrical responses in both the preferred and nonpreferred limb in different muscles assessed during cycling at different intensities within a range of 10%-20%. Although individual physiological differences that might be relevant in some clinical/performance settings should not be disregarded, these findings indicate that measuring a single lower limb provides an accurate approximation of the responses in both lower limbs.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

