Hu similarity coefficient: a clinically oriented metric to evaluate contour accuracy in radiation therapy
Harold Yang Hu1, Shaw Yang Hu2, Min Yang3
1Basis Scottsdale, Scottsdale, AZ, USA.
Abstract:
To propose a clinically oriented quantitative metric, Hu similarity coefficient (HSC), to evaluate contour quality, gauge the performance of auto contouring methods, and aid effective allocation of clinical resources. The HSC is defined as the ratio of the number of boundary points of the initial contour that doesn't require modifications over the number of boundary points of the final adjusted contour. To demonstrate the clinical utility of the HSC in contour evaluation, we used publicly available pelvic CT data from the Cancer Imaging Archive. The bladder was selected as the organ of interest. It was contoured by a certified medical dosimetrist and reviewed by a certified medical physicist. This contour served as the ground truth contour. From this contour, we simulated two contour sets. The first set had the same Dice similarity coefficient (DSC) but different HSCs, whereas the second set kept a constant HSC while exhibiting different DSCs. Four individuals were asked to adjust the simulated contours until they met clinical standards. The corresponding contour modification times were recorded and normalized by individual's manual contouring times from scratch. The normalized contour modification time was correlated to the HSC and DSC to evaluate their suitability as quantitative metrics assessing contour quality. The HSC maintained a strong correlation with the normalized contour modification time when both sets of simulated contours were included in analysis. The correlation between the DSC and normalized contour modification time, however, was weak. Compared to the DSC, the HSC is more suitable for evaluating contour quality. We demonstrated that the HSC correlated well with the average normalized contour modification time. Clinically, contour modification time is the most relevant factor in allocating clinical resources. Therefore, the HSC is better suited than the DSC to assess contour quality from a clinical perspective.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Related Concept Videos
Receiver Operating Characteristic Plot
Calibration Curves: Correlation Coefficient