Related Experiment Video
Updated: Jun 5, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
End-Tidal Oxygen as an Effective Noninvasive Measure of Preoxygenation during Rapid Sequence Intubation in the
Eric Boccio1, Justin Belsky2, Sandra Lopez1
1Department of Emergency Medicine, Memorial Healthcare System, Hollywood, Florida.
Background:
Preoxygenation is intended to extend the duration of apnea until desaturation occurs. End-tidal oxygen (ETO2) is the standard for measuring preoxygenation, however, peripheral capillary oxygen saturation (SpO2) is used more commonly within the emergency department.
Objective:
The primary aim was to determine whether patients were optimally preoxygenated as measured by ETO2 vs. SpO2 during rapid sequence intubation. Secondary aims investigated changes in these measurements before and after intubation and whether patient characteristics influenced the likelihood of preoxygenation success as measured by each of the modalities.
Methods:
A multicenter, prospective observational study of a convenience sample of patients undergoing rapid sequence intubation was performed. ETO2 and SpO2 were recorded at the cessation of preoxygenation (T1) and intubation completion (T2). Optimal preoxygenation was defined by an observed ETO2 level ≥ 90% and SpO2 level equal to 100% at T1.
Results:
Thirty patients were intubated and included in the analysis. Median ETO2 and SpO2 at T1 were 90.5% (interquartile range 86-93%) and 100% (interquartile range 97-100%), respectively. Preoxygenation success rates as measured by ETO2 and SpO2 were 56.7% and 53.3%, respectively (p = 0.431). The mean (SD) decrease in ETO2 during the intubation attempt was larger and more variable than that for SpO2 (25.8% [22.5%] vs. 2.1% [3.3%]; p < 0.001). Patient age, sex, and body mass index were not associated with likelihood of preoxygenation success for either modality.
Conclusions:
Preoxygenation success was similar when measured by strict ETO2 and SpO2 criteria. ETO2 is more sensitive to periods of apnea than SpO2 and may serve as an early indicator of an imminent desaturation event.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...