Related Experiment Video
Updated: Jun 5, 2025

Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation
Published on: September 13, 2015
Impact of different muscle-lengthening amplitudes combined with electrical nerve stimulation on torque production
Antoine Pineau1, Alain Martin1, Romuald Lepers1
1INSERM UMR1093-CAPS, Université Bourgogne, UFR des Sciences du Sport, Dijon, France.
Abstract:
This study investigated torque production resulting from the combined application of wide-pulse neuromuscular electrical stimulation (NMES), delivered over the posterior tibial nerve, and muscle lengthening at two distinct amplitudes. Wide-pulse NMES (pulse duration: 1 ms; stimulation intensity: 5-10% of maximal voluntary contraction) was delivered at both low- (20 Hz) and high- (100 Hz) stimulation frequencies, either alone (NMES condition) or combined with a muscle lengthening at two amplitudes (10 or 20° ankle joint rotation; NMES + LEN10 and NMES + LEN20 conditions, respectively). For each frequency, the torque-time integral (TTI) and the muscle activity following the cessation of stimulation trains (sustained EMG activity) were calculated. At 20 Hz, TTI was higher (P = 0.007) during NMES + LEN10 (233.2 ± 101.5 Nm·s) and NMES + LEN20 (229.2 ± 92.1 Nm·s) than during the NMES condition (187.5 ± 74.5 Nm·s), without any change in sustained EMG activity (P = 0.54). At 100 Hz, TTI was higher (P = 0.038) during NMES + LEN10 (226.6 ± 115.3 Nm·s) than during NMES + LEN20 (180.6 ± 84.0 Nm·s) and NMES (173.9 ± 94.9 Nm·s). This torque enhancement was accompanied by a higher sustained EMG activity (P = 0.045) in the NMES + LEN10 condition. These findings show that, for low-frequency NMES, significant torque increases were observed with both a 10- or a 20-degree lengthening amplitude, probably linked to increased afferents' activation. In contrast, with high-frequency NMES, a significant TTI enhancement was observed only with the 10-degree amplitude, accompanied by increased sustained EMG activity, suggesting neural mechanisms' involvement. When a greater lengthening amplitude was superimposed during high-frequency NMES, these mechanisms were probably inhibited, precluding torque enhancement.NEW & NOTEWORTHY This study demonstrates that combining wide-pulse low-frequency NMES and muscle lengthening can increase torque production compared with the sole application of NMES. Torque enhancement is most likely linked to the persistent firing of muscle afferents. Although muscle lengthening superimposition also permitted torque increases during wide-pulse high-frequency NMES, increasing the muscle lengthening amplitude did not allow further torque enhancements, probably due to presynaptic inhibitory mechanisms.
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Excitation-Contraction Coupling in Skeletal Muscles
When an action...
Relaxation of Skeletal Muscles
When an action potential reaches the axon terminal, it depolarizes the membrane and opens voltage-gated sodium channels. Sodium ions enter the cell, further depolarizing the presynaptic membrane. This depolarization causes voltage-gated calcium channels to open....
Generation of Action Potential in Skeletal Muscles
Like neurons, muscle cells are also regarded as excitable due to their capacity to change in response to stimuli, primarily due to voltage-gated ion channels embedded in their plasma membranes, which get activated by alterations in the...