Related Experiment Video
Updated: May 5, 2026

Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model
Published on: February 23, 2020
Detection of inflammation in abdominal aortic aneurysm with reduced field-of-view and low-b-value diffusion-weighted
Yi-Jun Pan1, Xiao-Lang Jiang2, Yan Shan1
1Department of Radiology, Zhongshan Hospital, Fudan University, No.180 Fenglin Road, Xuhui District, Shanghai 200032, China; Shanghai Institute of Medical Imaging, No.180 Fenglin Road, Xuhui District, Shanghai 200032, China.
Objectives:
To evaluate the performance of diffusion-weighted imaging (DWI) with an optimal b-value and field-of-view in identifying wall inflammation in abdominal aortic aneurysm (AAA) by comparing it to delayed enhancement T1-weighted imaging (DEI).
Methods:
Twenty-five males with AAA were prospectively enrolled and underwent fat-suppressed T1-weighted dark-blood imaging (T1WI), full field-of-view (f-FOV) and reduced field-of-view (r-FOV) DWI (b values = 0, 100, 400 and 800 s/mm2), and DEI. Corresponding images on f-FOV, r-FOV DWI and DEI at the same level were evaluated qualitatively and quantitatively using the paired t-test and Wilcoxon signed-rank test. The agreement in detecting wall inflammation between DWI and DEI sequences was analyzed using weighted kappa statistics.
Results:
For both r-FOV and f-FOV DWI, the scores of delineation of aneurysm wall and lesion conspicuity, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were highest on DWI₁₀₀ (Ps < 0.05). The scores of delineation of aneurysm wall, geometric distortion, lesion conspicuity, and SNR, CNR were significantly higher on r-FOV DWI than those on f-FOV DWI (Ps < 0.05). r-FOV DWI₁₀₀ showed comparable performance to DEI in detecting wall inflammation (κ = 0.715), with superior blood suppression and higher SNR and CNR (Ps < 0.05).
Conclusions:
DWI with r-FOV and low b-value could be a promising alternative to DEI in identifying wall inflammation in AAA.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aneurysm II: Clinical Manifestations and Diagnostic Studies