Related Experiment Video
Updated: Jun 5, 2025

Paramagnetic Relaxation Enhancement for Detecting and Characterizing Self-Associations of Intrinsically Disordered Proteins
Published on: September 23, 2021
Evaluation of Automatic Analysis Software for 1H NMR Spectra Quantification. Impact of Signal Broadening and EDTA
Circe C Hernández-Espino1, Martha E García-Aguilera1, Alan Emmanuel Aguilar Valeriano1
1Instituto de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria, Ciudad de México, Mexico.
Abstract:
NMR is a well-established analytical technique that enables the identification and quantification of several compounds in complex mixtures. The implementation of automated analysis software enhances this process by comparing sample spectra with a library of standard reference spectra. One of the key parameters in libraries is the signal line width; however, this may result in a concentration bias for compounds with broad signals, particularly those that are complexing. This study aims to evaluate the quantification of seven compounds commonly present in wine with complexing activity. Four automatic programs and manual deconvolution were used to quantify mixtures of these compounds at known concentrations, both in the presence of cations and with the addition of ethylenediamine-tetraacetate (EDTA) as a chelating agent. Additionally, malate was quantified in a wine sample using the standard addition method, both with and without EDTA. The findings illustrate that three of the programs, which employ the signal width value, underestimate compound concentrations in the presence of cations due to signal broadening. This error was mitigated by the EDTA addition. In contrast, the remaining software, which did not utilize signal line width, obtained similar concentrations in both cases. Future investigations involving the automatic analysis of compounds with complexing activity should take care of sample preparation and/or algorithm selection. Furthermore, future software development should consider allowing flexible adjustments of signal line width in their workflow.
More Related Videos
Related Concept Videos
¹H NMR Signal Integration: Overview
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectroscopy Of Amines
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

