An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Proximal Biceps Tenodesis - Biomechanical Analysis in Sheep: Comparison between Metallic Anchor, Onlay Bioabsorbable
Amauri João Orso1, Mateus Franceschi Dallanora1, Paulo Cesar Faiad Piluski1
1Serviço de Ortopedia e Traumatologia, Hospital São Vicente de Paulo/Instituto de Ortopedia e Traumatologia, Passo Fundo, RS, Brasil.
Abstract:
Objective To biomechanically evaluate different fixation devices for the proximal biceps in the humerus of sheep, comparing their fixation strength to failure, tendon displacement, and failure site in each technique. Methods A total of 27 humerus tests were performed on sheep, separating them into 3 groups: group A with tenodesis with metallic anchors ( n = 11), group B with biocomposite knotless devices ( n = 8) and group C with metallic interference screws ( n = 8), performing tenodesis with the sheep's own biceps, maintaining its native distal insertion. The three methods were submitted to a universal tensile testing machine. Results There was no statistically significant difference in the strength of fixation until failure and displacement between the tendons fixed by the different techniques. Regarding the pattern of ruptures, it was observed that most ruptures of the metallic anchors occurred at the level of the myotendinous junction, most of the bioabsorbable knotless anchors failed due to slippage of the wire-screw interface, and all interference screws failed via tendon slip. Conclusion The three techniques with metal anchor, onlay bioabsorbable knotless anchors, and interference screws are largely resistant to tensile loads for long head of the biceps tenodesis in sheep. There was no statistical difference between the three groups. Cyclic load resistance studies can provide more valuable data for comparing groups.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
06:36A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
Published on: December 10, 2021
Related Concept Videos
Mechanical Protein Functions
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Two Force Member
Machines: Problem Solving II
Bearings: Problem Solving
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...