Temporal changes in device-derived daily activity related to ventricular arrhythmias from the CERTITUDE registry
Valentina Kutyifa1, Michael Christof1, Steven Mullane2
1Division of Cardiology, Department of Medicine, University of Rochester, Rochester, New York.
Background:
There have been limited data examining the temporal relationship between device-derived daily activity and ventricular arrhythmias (VAs).
Objective:
We aimed to assess whether activity predicted VAs or VAs predicted changes in activity.
Methods:
The CERTITUDE registry includes over 55,000 implanted devices active on Home Monitoring. Daily data on activity are captured by a 1-axis accelerometer. Temporal changes in activity during treated VAs were analyzed using the first event and 7-day activity windows (baseline, pre-event, and postevent). Baseline period was defined as 31 to 38 days prior to VA. VAs were categorized by heart rate (≤200 beats/min, >200 beats/min) and treatment (shock or antitachycardia pacing). Differences were assessed using the binomial proportion test and case-crossover analysis.
Results:
A total of 5631 devices (3688 implantable cardioverter-defibrillators, 1943 cardiac resynchronization therapy defibrillators) were analyzed with a cumulative follow-up duration of 18,354 years (5.6 million days). Patients with VA events >200 beats/min with shock (n = 593) had a significant decline in activity post-VA with a median -8.7% reduction (interquartile range -24.6% to 7.3%, P < 0.001). However, there was no reduction in activity before VA events >200 beats/min (P = .690) or before or after VA events >200 beats/min with antitachycardia pacing. However, VA events ≤200 beats/min with shock had reductions in activity following the event (-5.8%, interquartile range -29.5% to 12.3%, P = .003). Case-crossover analyses confirmed lower activity rates following for VA events >200 beats/min with shock.
Conclusion:
In the CERTITUDE registry, we have shown a temporal decline in device-derived activity following VA events >200 beats/min and for VA events <200 beats/min treated with a shock, but we did not find changes in activity preceding a shock event.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
06:07Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Mechanism of Cardiac Arrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...