Related Experiment Video
Updated: Jun 5, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
The shard test and nanoporomechanics reverse classical paradigm of cement hydration being contractive
Raúl E Marrero Rosa1, Tapiwanashe Bhibho1, Ahmet A Dőnmez2
1Civil and Environmental Engineering Department, Northwestern University, Evanston, IL 60208.
Abstract:
Le Chatelier in 1887 and Powers in 1947 demonstrated that the volume of nanoscale C-S-H (calcium silicate hydrate) particles formed during hydration is smaller than the combined volume of the reactants-the anhydrous Portland cement and water. Hydration has thus been considered as contractive. An experiment shows that the opposite is true above the nanoscale. The porous skeleton of cement paste expands as the growing C-S-H particles push each other apart, similar to crystal growth pressure. This is significant for high-performance concretes (HPC) with low water-cement ratios (w/c [Formula: see text] 0.4), where chemical self-desiccation lowers pore relative humidity by 40%, compared to just 1% in traditional concretes (w/c [Formula: see text] 0.5). Standard American Society for Testing and Materials (ASTM) C1608 tests, using 10 mm thick water-immersed specimens, show large shrinkage because the half-time of water ingress is many decades, unable to offset shrinkage-causing self-desiccation. The present experiment, using a laser microscopy-topography technique, proves the opposite-expansion, evidenced by measuring the length changes of water-immersed HPC shards 0.5 mm thick in which the diffusion halftime, only about one hour, allows continuous resaturation of pores, canceling self-desiccation. The faster diffusion (halftime of one hour) enables continuous pore resaturation, preventing shrinkage. When sealed with paraffin oil, the shards self-desiccate and shrink. These findings align with studies since 2015, showing that models excluding hydration expansion cannot fit test data across various specimen sizes and sealing conditions. The results suggest that standardized ASTM tests for the so-called chemical shrinkage in modern concretes with very low water-cement ratios are misleading and need revision.
More Related Videos
Related Concept Videos
Hydration of Cement
Porosity in Cement Paste
The balance of water to cement in the mix is...
Pore Size Distribution
Adequate...
Microcracking in Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...