Related Experiment Video
Updated: Jun 5, 2025

A Tactile Automated Passive-Finger Stimulator TAPS
Published on: June 3, 2009
The Psychophysical Assessments of Tactile, Temperature and Electrical Perception for Implants With Metal Prosthetic
Qing Fang1, Jinlang Xue1, Shuai Hu1
1Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji Research Institute of Stomatology, and Department of Prosthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai 200072, China.
Abstract:
Tactile function and thermal perception are 2 primary functions of oral structures. Implants without periodontal ligaments and pulp might fail to sense tactile and temperature changes. This study aimed to investigate implants' tactile, thermal, and electrical perception by detailed psychophysical assessments. A total of 48 patients with single implant restoration were recruited. Mechanical (5 intensities), cold (4 temperatures), and electrical stimulation were, respectively, applied to implants and natural teeth, and the psychophysical results were recorded with a visual analog scale and compared between implants and natural teeth. For tactile perception, at low and medium forces, implants were significantly poorer than natural teeth (P < .01), but at the largest force, there were no significant differences (P > .05). Regarding thermal perception, thermal changes on implants could be detected although the signals were weaker when compared with natural teeth (P < .01). Implants were less sensitive to electrical stimulation than natural teeth (P < .01). Even though there is no periodontium and pulp, dental implants could perceive the mechanical, thermal, and electrical stimulation weakly.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Thermosensation