Related Experiment Video
Updated: May 11, 2026

11:38
Influence of Hybrid Perovskite Fabrication Methods on Film Formation, Electronic Structure, and Solar Cell Performance
Published on: February 27, 2017
18.4K
High-Performance Perovskite Flat Panel X-Ray Imagers via Blade Coating.
Aiping Zhang1,2, Shujie Tie1, Xiaojuan Lu1
1Sichuan Research Center of New Materials, Institute of Chemical Materials, China Academy of Engineering Physics, Chengdu, 610200, China.
Small Methods
|December 10, 2024
Summary
Researchers developed a new blade-coating method for fabricating large, uniform perovskite X-ray detector films. This breakthrough enables high-performance flat-panel X-ray imagers for low-dose applications.
Area of Science:
- Materials Science
- Medical Imaging
- Detector Physics
Background:
- Perovskite X-ray detectors offer superior performance for low-dose imaging.
- Fabricating large-area, uniform, and stable perovskite films for flat-panel X-ray imagers (FPXIs) remains a significant challenge.
- A scalable synthesis route is crucial for commercializing perovskite X-ray detector technology.
Purpose of the Study:
- To develop a general synthesis route for large-scale halide perovskite thick films on thin-film transistor (TFT) backplanes.
- To enable high-throughput manufacturing of uniform and stable perovskite films for FPXIs.
- To bridge the gap between perovskite detector potential and market entry.
Main Methods:
- Development of an advanced precursor paste optimized for blade coating.
- Direct deposition of 300-micrometer thick perovskite films onto pixeled TFT substrates using blade coating.
- Characterization of film uniformity, dark current, noise, sensitivity, limit of detection, and spatial resolution.
Main Results:
- Achieved highly uniform 300-micrometer thick perovskite films via blade coating.
- Demonstrated stable dark current and minimal noise in the fabricated X-ray detectors.
- Attained high sensitivity (15200 µC Gyair -1 cm-2), low limit of detection (26.8 nGyair s-1), and excellent spatial resolution (0.95 lp mm-1) with negligible crosstalk.
Conclusions:
- The developed blade-coating method provides a high-throughput manufacturing solution for large-area perovskite X-ray detector films.
- The fabricated (BA)2(MA)9Pb10I31 perovskite FPXIs exhibit promising performance for advanced X-ray imaging.
- This work facilitates the market entry of perovskite-based low-dose X-ray detectors.
Related Concept Videos
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.