Inter-Rater Reliability of Ultrasonographic Measurements of Optic Nerve Sheath Diameter Performed by Emergency Nurses
Introduction:
We aimed to determine the inter-rater reliability of ultrasonographic optic nerve sheath diameter measurements performed by emergency nurses.
Methods:
Point-of-care ultrasound of the optic nerve sheath diameter measurements were performed in B-mode using a 10 MHz linear probe. The emergency nurses had no previous experience in ultrasonography. Emergency nurses performed sonographic measurements on patients in groups of 2. First, 1 emergency nurse measured optic nerve sheath diameter in both the right and left eyes of the patient, and then the other emergency nurse measured optic nerve sheath diameter in the right and left eyes of the same patient. Thus, a total of 4 optic nerve sheath diameter measurements were made by 2 emergency nurses in both eyes of 1 patient. Four emergency nurses measured optic nerve sheath diameter in 25 separate patients. As a result, a total of 600 optic nerve sheath diameter values were obtained in 150 patients. Each emergency nurse recorded their results on data collection forms and was blinded to each other's measurements.
Results:
The median optic nerve sheath diameter was 3.6 mm (interquartile range, 0.6). The median optic nerve sheath diameters of males and females were 3.7 mm (interquartile range, 0.6) and 3.5 mm (interquartile range, 0.6), respectively. The intraclass correlation coefficient was 0.89 (95% CI, 0.86-0.91). The intraclass correlation coefficient values for the optic nerve sheath diameter measurements of the right and left eyes were 0.89 (95% CI, 0.85-0.92) and 0.88 (95% CI, 0.83-0.91), respectively.
Discussion:
There is good inter-rater reliability among emergency nurses with no previous experience in measuring the optic nerve sheath diameter with point-of-care ultrasound.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...