Intra-individual Differences in Pericoronary Fat Attenuation Index Measurements Between Photon-counting and
Giuseppe Tremamunno1, Milan Vecsey-Nagy2, Muhammad Taha Hagar3
1Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (G.T., M.V-N., M.T.H., J.O., A.V-S., T.E., D.K.); Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189 Rome, Italy (G.T.).
Rationale And Objectives:
The purpose of this study was to explore intra-individual differences in pericoronary adipose tissue (PCAT) fat attenuation index (FAI) between photon-counting detector (PCD)- and energy-integrating detector (EID)-CT.
Material And Methods:
Patients were prospectively enrolled for a PCD-CT research scan within 30 days of EID-CT. Both acquisitions were reconstructed using a Qr36 kernel at 0.6 mm slice thickness (EID and PCD-down-sampled [DS]) and at 0.2 mm ultra-high resolution (UHR) for the PCD-CT. Iterative reconstruction was turned "off" (filter back projection used as alternative reconstruction method) or set to a recommended level in current literature. Coronary PCAT FAI was measured automatically using established thresholds of -190 to -30 HU at a set distance and radius. Statistical testing was performed using repeated-measures ANOVA and Bonferroni's multiple comparison tests (p significance was determined to be <0.003).
Results:
In total, 40 patients (mean age 68±8 years, 32 males [80%]) were included for analysis. Absolute FAI measurements differed significantly for all vessels between all reconstructions in the ANOVA comparison (all p<.001). The FAI decreased going from EID-CT to PCD-DS, to PCD-UHR with iterative reconstruction turned off (e.g. right coronary artery: EID-CT: -76.5±8.9 vs -80.9±7.0 vs -88.3±6.7 HU, respectively; p < 0.001). The mean FAI of datasets using iterative reconstruction did not demonstrate significant differences on multiple comparisons (e.g. left circumflex artery: EID: -65.7±8.5; PCD-DS: -66.0±7.4; PCD-UHR: -67.8±7.0 HU, respectively; p>0.06).
Conclusion:
Intra-individual absolute PCAT FAI measurements differ significantly between EID- and PCD-CT when controlling for reconstruction kernel and slice thickness. However, the use of iterative reconstruction minimizes most differences in FAI, enabling inter-scanner comparability.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
