Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION
David Szanto1, Michael Wall2, Luke X Chong3
1Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Translational Vision Science & Technology
|December 12, 2024
Summary
Visual field testing with larger stimulus size V shows patterns similar to size III in glaucoma and NAION. This supports using size V for monitoring moderate to severe vision loss.
Area of Science:
- Ophthalmology
- Neuro-ophthalmology
- Visual electrophysiology
Background:
- Anterior optic nerve disorders create distinct visual field (VF) archetypes (ATs).
- Standard automated perimetry uses different stimulus sizes, with size V potentially reducing variability in advanced vision loss.
Purpose of the Study:
- To determine if VF testing with stimulus size III and size V yields similar ATs in glaucoma and nonarteritic anterior ischemic optic neuropathy (NAION).
- To assess the utility of size V VFs in capturing disease-specific patterns.
Main Methods:
- Archetypal analysis (AA) was performed on 1969 same-day VF pairs (size III and size V) from glaucoma and NAION datasets.
- Raw sensitivities were censored and age-standardized before analysis.
- ATs from separate stimuli were compared using cosine similarity.
Main Results:
- AA identified 14 ATs applicable to both glaucoma and NAION.
- Similar patterns were observed between size III and size V VFs, with 87% of AT pairings showing high cosine similarity (≥0.8).
- Combined ATs effectively retained patterns from individual stimulus VFs.
Conclusions:
- VF testing using stimulus size V demonstrates quantifiable patterns comparable to size III.
- Size V VFs are suitable for monitoring VF progression in moderate to severe glaucoma and NAION.
- This finding supports the use of size V for consistent monitoring across different stimulus sizes.
Related Concept Videos
Glaucoma: Overview
507
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
507
Anatomy of the Eyeball
6.0K
The eye is a spherical, hollow structure composed of three tissue layers. The outer layer — the fibrous tunic, comprises the sclera — a white structure — and the cornea, which is transparent. The sclera encompasses some of the ocular surface, most of which is not visible. However, the 'white of the eye' is distinctively visible in humans compared to other species. The cornea, a clear covering at the front of the eye, enables light penetration. The eye's middle...
6.0K
Vision
52.9K
Vision is the result of light being detected and transduced into neural signals by the retina of the eye. This information is then further analyzed and interpreted by the brain. First, light enters the front of the eye and is focused by the cornea and lens onto the retina—a thin sheet of neural tissue lining the back of the eye. Because of refraction through the convex lens of the eye, images are projected onto the retina upside-down and reversed.
52.9K
Photoreceptors and Visual Pathways
5.7K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
5.7K