Related Experiment Video
Updated: Jul 28, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Errors in measurement of oxygen uptake due to anesthetic gases
Abstract:
Errors in measurement of exhaled gas volume, mixed expired oxygen and carbon dioxide concentrations, and inspired oxygen concentration and the presence of exhaled anesthetic agents cause errors in on-line calculated oxygen uptake that increase geometrically with increasing inspired oxygen concentration. No one has quantified the decrease in the magnitude of the error that might be realized if directly measured nitrogen concentration were included in the calculation. We used a computer model to evaluate this improvement, assuming an oxygen uptake of 200 ml/min and normal ventilatory parameters. Using a Monte Carlo technique, we generated 100 sets of data points, with random errors averaging 0.5% around the expected gas concentrations, and compared the accuracy of oxygen uptake calculated with and without inclusion of directly measured inspired and expired nitrogen concentrations. When the inspired oxygen fractions were 0.2, 0.5, and 0.8, the calculated oxygen uptakes +/- % standard deviation were 200 +/- 4.3, 200 +/- 12, and 196 +/- 21 when directly measured nitrogen was included versus 200 +/- 3.5, 196 +/- 16, and 205 +/- 71 when it was not. The procedure was repeated, assuming 50 ml/min of anesthetic excretion and the calculated oxygen uptakes were 200 +/- 4.6, 202 +/- 12, and 195 +/- 17 versus 212 +/- 3.8, 251 +/- 17, and 398 +/- 64. Including direct measurement of inhaled and exhaled concentrations of nitrogen or another insoluble inert tracer gas allows accurate measurement of oxygen uptake, even in the presence of exhaled anesthetic gases. It also decreases the error in oxygen uptake determination by a factor of nearly six when the inhaled oxygen fraction is 0.8.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Inhalational Anesthetics: Overview
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...