Compression ratio: a novel method to quantify compressibility as a diagnostic measurement in giant cell arteritis
Muhammad Asim Khurshid1, Daniel Mynors-Wallis2, Selwyn Richards1
1Department of Rheumatology, University Hospitals Dorset NHS Foundation Trust, Dorset, UK.
Objectives:
Ultrasonographic assessment of giant cell arteritis (GCA) relies on the demonstration of a non-compressible halo. Several ultrasonographic methods have been developed to quantify arterial wall thickness; however, arterial compressibility has not been quantified. This study presents a possible solution for quantifying compressibility to assist in diagnosing GCA.
Methods:
Cross-sectional areas of uncompressed and compressed arteries were measured ultrasonographically, and their ratio was calculated [compression ratio (CR)]. The values obtained were tested for a relationship with the diagnosis of GCA and diagnostic performance was compared against halo count (HC).
Results:
Ultrasound findings from 304 patients (65.8% females) were divided into GCA arm (n = 72) and Not-GCA arm (n = 232). The CR values for patients in the GCA arm were significantly lower than the Not-GCA arm whether compared as the individual patient mean or lowest CR value (Mann-Whitney U test P <0.001). The CR values observed in this study from a single skilled clinician suggest a threshold CR value of ≤2.3 for predicting a diagnosis of GCA. If confirmed in other studies this would effectively provide a quantitative measure that might help training sonographers confirm a visually identified halo sign and enhance objectivity in ultrasonographic assessment of GCA.
Conclusion:
Compression ratio (CR) is a novel quantifiable measure that contributes to the ultrasound assessment of GCA. It is worthy of further research and in clinical application, it is a measurement that may enhance diagnostic certainty.
More Related Videos
06:35An Immunohistopathologic Study to Profile the Folate Receptor Beta Macrophage and Vascular Immune Microenvironment in Giant Cell Arteritis
Published on: February 8, 2019
09:06Measurement of the Compressibility of Cell and Nucleus Based on Acoustofluidic Microdevice
Published on: July 14, 2022
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: