Optimal configuration of hydrogen storage capacity of hybrid microgrid considering peak regulation and frequency

Dan Yu1, Yuhan Guo1, Weijun Zhu1

  • 1Zhejiang Huayun Electric Power Engineering Design Consulting Co., Ltd., Hangzhou, Zhejiang, 310000, China.

Heliyon
|December 16, 2024
PubMed

Related Concept Videos

Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
161
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
121
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
252
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
155
Energy Stored in Capacitors01:10

Energy Stored in Capacitors

A parallel plate capacitor, when connected to a battery, develops a potential difference across its plates. This potential difference is key to the operation of the capacitor, as it determines how much electrical energy the capacitor can store.
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
434
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
94