Related Experiment Video
Updated: Jul 16, 2026

Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies
Published on: January 28, 2014
Within- and between-subject biological variation data for whole blood HbA1c from 38 apparently healthy Turkish
Murat Keleş1, Gönül Ünver Şeker2
1Alanya Alaaddin Keykubat University Alanya Education And Research Hospital, Antalya, Turkey.
HbA1c plays an important role in the diagnosis and treatment of diabetes and is a valuable biomarker for evaluating glycemic control and predicting the risk of vascular complications. The study aimed to determine the biological variation (BV) for HbA1c and thereby contribute to analytical performance specifications, reference change values, and index of individuality. Fasting venous whole blood samples were collected from 38 presumably healthy subjects (20 females, 18 males) once a week for ten weeks, and analyzed in duplicate using the Roche Cobas c501 analyzer. BioVar, an online R-based biological variation analysis tool, was used for the statistical analysis. BV values were obtained by analysis of variance (ANOVA) after outlier detection, normality tests, steady-state, and homogeneity checks. The within-subject biological variation for HbA1c was 2.9%, and the between-subject biological variation was 7.9%. The index of the individuality of HbA1c was 0.37. Derived desirable analytical goals for imprecision, bias, total allowable error, and maximum expanded allowable measurement uncertainty were 1.4%, 1.8%, 4.2%, and 2.9% respectively. The reference change value is more appropriate for interpreting HbA1c results than a population-based reference interval.
HbA1c plays an important role in the diagnosis and treatment of diabetes and is a valuable biomarker for evaluating glycemic control and predicting the risk of vascular complications. The study aimed to determine the biological variation (BV) for HbA1c and thereby contribute to analytical performance specifications, reference change values, and index of individuality. Fasting venous whole blood samples were collected from 38 presumably healthy subjects (20 females, 18 males) once a week for ten weeks, and analyzed in duplicate using the Roche Cobas c501 analyzer. BioVar, an online R-based biological variation analysis tool, was used for the statistical analysis. BV values were obtained by analysis of variance (ANOVA) after outlier detection, normality tests, steady-state, and homogeneity checks. The within-subject biological variation for HbA1c was 2.9%, and the between-subject biological variation was 7.9%. The index of the individuality of HbA1c was 0.37. Derived desirable analytical goals for imprecision, bias, total allowable error, and maximum expanded allowable measurement uncertainty were 1.4%, 1.8%, 4.2%, and 2.9% respectively. The reference change value is more appropriate for interpreting HbA1c results than a population-based reference interval.
More Related Videos
11:28Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Published on: March 13, 2015
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025