Assessing radiation exposure of fingers of PET/CT technologists during18F-FDG procedures using active extremity
Vijitha Ramanathan1, S P Gamage1, Uiu Karunathilaka1
1Department of Radiography & Radiotherapy, Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka.
Abstract:
Extremity radiation exposure in nuclear medicine is a growing concern because it may surpass the maximum permissible dose of 500 mSv. This study aimed to assess the occupational finger dose received by technologists during the preparation and administration of18F-FDG radiopharmaceuticals in positron emission tomography-computed tomography (PET-CT) whole-body scan procedures. Fifty scans were selected, with one procedure excluded due to a high administered activity. The mean administered activity per scan was 207.2 ± 41.8 MBq, with preparation and administration times averaging 1.44 ± 1.30 min and 0.46 ± 0.31 min, respectively. The technologist's mean total finger dose received during preparation and administration was 253.5 ± 153.3 µSv per procedure. A significant positive correlation was found between the administered activity and occupational dose, with patient's body mass index, preparation time, and administration time also contributing to dose variation. Based on 703 PET-CT procedures conducted in 2022, the estimated occupational finger dose for a technologist was 178.2 mSv annually. This value is well below the International Commission on Radiological Protection's maximum permissible dose of 500 mSv. The findings of this study have a significant impact on extremity dosimetry in nuclear medicine in Sri Lanka, as this is the first study of its kind.
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET