Related Experiment Video
Updated: Jun 4, 2025

Examining Changes in HRV and Emotion Following Artmaking with Three Different Art Materials
Published on: January 11, 2020
Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring
Tian Liang1, Gizem Yilmaz1, Chun-Siong Soon1
1Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore (NUS), Singapore 117549, Singapore.
Abstract:
Cardiovascular diseases are a major cause of mortality worldwide. Long-term monitoring of nighttime heart rate (HR) and heart rate variability (HRV) may be useful in identifying latent cardiovascular risk. The Oura Ring has shown excellent correlation only with ECG-derived HR, but not HRV. We thus assessed if stringent data quality filters can improve the accuracy of time-domain and frequency-domain HRV measures. 92 younger (<45 years) and 22 older (≥45 years) participants from two in-lab sleep studies with concurrent overnight Oura and ECG data acquisition were analyzed. For each 5 min segment during time-in-bed, the validity proportion (percentage of interbeat intervals rated as valid) was calculated. We evaluated the accuracy of Oura-derived HR and HRV measures against ECG at different validity proportion thresholds: 80%, 50%, and 30%; and aggregated over different durations: 5 min, 30 min, and Night-level. Strong correlation and agreements were obtained for both age groups across all HR and HRV metrics and window sizes. More stringent validity proportion thresholds and averaging over longer time windows (i.e., 30 min and night) improved accuracy. Higher discrepancies were found for HRV measures, with more than half of older participants exceeding 10% Median Absolute Percentage Error. Accurate HRV measures can be obtained from Oura's PPG-derived signals with a stringent validity proportion threshold of around 80% for each 5 min segment and aggregating over time windows of at least 30 min.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...