Related Experiment Video
Updated: May 6, 2026

Lensless Fluorescent Microscopy on a Chip
Published on: August 17, 2011
Dual-Wavelength On-Chip Integrated Metalens for Epi-Fluorescence Single-Molecule Sensing
Elena Barulina1, Dang Du Nguyen2,3, Fedor Shuklin1
1Moscow Center for Advanced Studies, Kulakova str. 20, 123592 Moscow, Russia.
Abstract:
Single-molecule fluorescence spectroscopy offers unique capabilities for the low-concentration sensing and probing of molecular dynmics. However, employing such a methodology for versatile sensing and diagnostics under point-of-care demands device miniaturization to lab-on-a-chip size. In this study, we numerically design metalenses with high numerical aperture (NA = 1.1), which are composed of silicon nitride nanostructures deposited on a waveguide and can selectively focus guided light into an aqueous solution at two wavelengths of interest in the spectral range of 500-780 nm. Despite the severe chromatic focal shift in the lateral directions owing to the wavelength-dependent propagation constant in a waveguide, segmented on-chip metalenses provide perfectly overlapping focal volumes that meet the requirements for epi-fluorescence light collection. We demonstrate that the molecule detection efficiencies of metalenses designed for the excitation and emission wavelengths of ATTO 490LS, Alexa 555, and APC-Cy7 tandem fluorophores are sufficient to collect several thousand photons per second per molecule at modest excitation rate constants. Such sensitivity provides reliable diffusion fluorescence correlation spectroscopy analysis of single molecules on a chip to extract their concentration and diffusion properties in the nanomolar range. Achromatic on-chip metalenses open new avenues for developing ultra-compact and sensitive devices for precision medicine and environmental monitoring.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Metal-Semiconductor Junctions
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...

