Related Experiment Video
Updated: Jun 4, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Performance evaluation of a bi-directional synchronous H6 inverter for AC/DC system interaction with SiC and Si-Based
Meshari S Alshammari1, Alireza Namadmalan2, Maeve Duffy2
1Electrical Engineering Department, College of Engineering, Jouf University, Sakaka, Aljouf, Saudi Arabia.
Abstract:
The bidirectional inverter connected to the grid is a crucial component of DC distribution systems, however its operation can have an impact on the systems' overall efficiency. The usual load profile of such systems in residential buildings is quite dynamic, with multiple periods of light load, especially when compared to high-demand sectors. This study examines and contrasts the impact of SiC and Si power MOSFETs on the best configuration of a 5 kW bidirectional H6 inverter specifically designed for residential use applications. Analytical modeling based on PSIM simulation results is employed to predict losses in a transformer-less synchronous H6 topology. Results of a 5 kW system indicate that silicon carbide (SiC) has an efficiency of up to 98.3%, surpassing the 93.6% efficiency attained with silicon (Si). Furthermore, this study explores potential of further improving efficiency by increasing the operating frequency to 50 kHz. The increase in frequency also leads to a reduction in the size of passive components. The experimental findings of a 1 kW system corroborate the efficacy of the proposed bidirectional synchronous H6 inverter topology, by demonstrating roughly the same trend in terms of the level of improvement over the baseline performance. It has been established that the use of SiC MOSFETs is superior to the use of Si MOSFETs, and that the appropriate operating frequency for bidirectional synchronous and comparable applications is 20 kHz rather than 50 kHz.
More Related Videos
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Source Transformation for AC Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Half wave rectifier
Three-Phase Circuits