Mixed-mode separation of antisense oligonucleotides using a single column with complementary anion-exchange and
Artaches A Kazarian1, Jung Hwa Lee1, Branko Mitasev1
1Genetics Guided Dementia Discovery (G2D2), Eisai, Inc. 35 Cambridge Park Drive, Suite 200, Cambridge, MA, 02140, USA.
Abstract:
The current study investigates the use of mixed-mode chromatography as a combination of anion-exchange (AEX) and hydrophobic interaction chromatography (HIC) for the analysis and purification of single-stranded antisense oligonucleotides with stereo-controlled phosphorothioate inter- nucleotide linkages. Initially a Scherzo-SS-C18 trimodal stationary phase with reversed-phase/AEX/ cation-exchange (CEX) functionalities is systematically evaluated to reveal the presence of U-shaped retention composed of two retention modes namely AEX and HIC, where the latter was also observed on related trimodal Scherzo SM and SW analogues. For the first time, retention and separation of deprotected oligonucleotides was described on a single mixed-mode column using a combination of AEX and HIC. This methodology was later applied to an alternative reversed-phase/AEX support, Newcrom BH, displaying similar retention trends under dual salt / organic modifier gradients. The merit of the method was assessed on the basis of separations between a phosphodiester (PO) impurity and phosphorothioate (PS) target for an assortment of selected 2'-O-methoxyethyl 18- to 20-mer single-stranded antisense oligonucleotides. Various parameters were evaluated mostly under HIC conditions including organic modifier percentage, type of salt, temperature, pH and type of buffer in the mobile phase. Retention of the oligonucleotides was significantly affected by the acetonitrile composition and the type of salt ((NH4)2SO4, NaBr, NaCl) where the latter NaCl also afforded resolution between the PS target and closely eluting PO impurities. Small changes in pH between 6.5 and 7 using MES and TRIS respectively demonstrated notable differences in retention and resolution. The optimized methods were compared against a range of traditional supports and applied to various mixed-mode analogues, possessing embedded amino acid, complex forming weak cation-exchange and terminal strong cation-exchange functionalities. The mixed-mode supports displayed HIC retention and better resolution between PS target and PO impurity was evident with a more focused 5 % acetonitrile gradient over its 10 % counterpart. Overall, throughout the study AEX and HIC demonstrated comparable resolution trends. Finally, the optimized HIC method was applied to a selected 18-mer antisense oligonucleotide at semi-preparative scale using the Newcrom BH column, affording purities of 60-80 % and recoveries of 52-76 %. Although HIC does not provide better separations between PS and PO than AEX, it opens possibilities to operate under non-denaturing conditions and allows purification of samples containing high salt content, as a standalone method or post AEX without a prior desalting step, which can result in 20-30 % sample loss.
More Related Videos
10:32On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Affinity Chromatography
Ion Exchange
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: