Preparation of REE-doped CaF2 single crystals for accurate determination of REE concentrations in CaF2 crystals via UV-LA-ICP-MS
Related Experiment Video
Updated: Apr 30, 2026

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Hui Hu1, Jianzong Zhou2, Ying Ye3
1Key Laboratory of Testing and Tracing of Rare Earth Products, State Administration for Market Regulation, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China; Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China.
Abstract:
Accurate determination of rare earth element (REE) concentrations in CaF2 crystals using UV-LA-ICP-MS is important but challenging due to the lack of matrix-matched reference materials. In this study, a REE-doped CaF2 single crystal (CaF2-05), prepared via the Bridgman-Stockbarger technique, was systematically characterized to assess its optical properties, homogeneity, and stability. Analyses using portable laser irradiation, UV-vis spectroscopy, back scatter electron (BSE) imaging, and cathodoluminescence (CL) demonstrated that the crystal possesses high optical quality and exhibits distinct optical adsorption properties compared to the silicate reference material NIST SRM 610. The within-unit variation (Sr) ranged from 3.82 % to 9.86 %, the between-unit Sr varied from 3.94 % to 7.85 %, and the mean square weighted deviation (MSWD) was close to 1, indicating minimal chemical heterogeneity. These results are comparable to those of certified reference materials and other home-made calibration standards. Femtosecond LA-ICP-MS mapping further confirmed the homogeneous distribution of REEs within the CaF2 crystal. Stability tests conducted from April to November 2024 demonstrated the crystal's good long-term stability. The method's accuracy was validated by calibrating REE concentrations in another CaF2 single crystal (CaF2-005), with measured REE concentrations closely matching reference values. The relative deviations (Dr) primarily ranged from -10.10 % to 12.79 %, which is significantly more accurate than the non-matrix-matched calibration using NIST SRM 610. These findings demonstrate that this method provides reliable accuracy and holds promise for application in the accurate determination of REE concentrations in CaF2-matrix samples, such as CaF2 luminescent materials and natural fluorite ores.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
07:24Quantitative Atomic-Site Analysis of Functional Dopants/Point Defects in Crystalline Materials by Electron-Channeling-Enhanced Microanalysis
Published on: May 10, 2021
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....