Background:
Accurate discrimination of functionally significant coronary stenosis using intravascular imaging remains uncertain, particularly with regard to vessel size. This meta-analysis evaluates the diagnostic performance of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for identifying functionally significant coronary stenosis as confirmed by fractional flow reserve (FFR).
Methods:
A systematic search of PubMed, Scopus and Google Scholar identified studies that assessed the diagnostic accuracy of IVUS and OCT by minimal luminal area (MLA) with FFR as the reference standard. Sensitivity and specificity were analysed across different vessel diameters including left main coronary artery (LM) lesions. Hierarchical models estimated the summary receiver operating characteristic curve, sensitivity and specificity.
Results:
31 studies involving 4039 patients and 4413 lesions were analysed. For IVUS, a median MLA threshold of 2.9 mm² (IQR: 2.6-3.2) predicted significant lesions, yielding an area under the curve (AUC) of 0.76. In vessels≥3 mm, this threshold increased to 3.0 mm² (IQR: 2.7-3.1) with an AUC of 0.76 while in smaller vessels it decreased to 2.6 mm² (IQR: 2.4-2.7) with an AUC of 0.79. For LM lesions, the median threshold was 6.0 mm² (IQR: 4.9-6.2) with an AUC of 0.88. OCT demonstrated a median threshold of 2.0 mm² (IQR: 1.7-2.3) and an AUC of 0.82 with better performance in larger vessels (≥3 mm, median 3.0 mm², AUC 0.87) than in smaller ones (<3 mm, median 1.8 mm², AUC 0.75).
Conclusions:
IVUS and OCT show moderate diagnostic accuracy for identifying functionally significant coronary stenosis with OCT providing improved accuracy in vessels≥3 mm. IVUS is more accurate in assessing LM lesions, suggesting that vessel size should guide modality selection.
Prospero Registration Number:
CRD 42024514538.
More Related Videos
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...