Diameter thresholds for pure ground-glass pulmonary nodules at low-dose CT screening: Chinese experience
Wenjun Ye1,2, Wenhai Fu1, Caichen Li1
1Department of Thoracic Surgery and Oncology, the First Affiliated Hospital of Guangzhou Medical University, State Key Laboratory of Respiratory Disease & National Clinical Research Center for Respiratory Disease, Guangzhou, China.
Background:
Limited research exists on screening thresholds for low-dose CT in detecting malignant pure ground-glass lung nodules (pGGNs) in the Chinese population.
Materials And Methods:
A retrospective analysis of the Guangzhou Lung-Care programme was conducted, retrieving average transverse diameter, location, histopathology, frequency and follow-up intervals. Diagnostic performances for 'lung cancers' were evaluated using areas under the curve (AUCs), decision curve analysis (DCA), sensitivities and specificities, with thresholds ranging from 5 mm to 10 mm. We divide malignant pGGNs into three groups: (1) minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA), (2) atypical adenomatous hyperplasia (AAH) and adenocarcinoma in situ (AIS) and MIA and IA and (3) IA-only.
Results:
In 'MIA+IA', increasing the threshold from 5 mm to 8 mm improved specificity (60.97% to 88.85%, p<0.001) and positive predictive values (PPVs; 5.87% to 14.88%, p<0.001), but decreased sensitivity (94.44% to 75.56%, p<0.001). Further raising threshold from 8 mm reduced sensitivity (75.56% to 60.00%, p<0.001), while slightly increasing specificity (88.85% to 93.47%, p<0.001) and PPVs (14.88% to 19.15%, p<0.001). Increasing threshold from 5 mm to 7 mm enhanced the AUC for 'MIA+IA' (from 0.711 to 0.829), 'AAH+AIS+MIA+IA' (from 0.748 to 0.804) and 'IA-only' (from 0.783 to 0.833). At 8 mm, the AUCs for these categories were similar. However, increasing the threshold from 7 mm to 10 mm resulted in reduced AUCs for 'MIA+IA' (0.829 to 0.767), 'AAH+AIS+MIA+IA' (0.804 to 0.744) and 'IA-only' (0.833 to 0.800). DCA reveals that the 8 mm predictive model demonstrates greater clinical utility compared with models with other thresholds.
Conclusions:
Increasing the diameter threshold for positive results for pGGNs, up to 8 mm could enhance diagnostic performance.
Trial Registration Number:
NCT04938804.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...