Guidelines for Elective Pediatric Fiberoptic Intubation
Published on: January 17, 2011
Pressure support ventilation improves ventilation during inhalational induction of anesthesia in children: A pilot
Viviane Lauret1, Claude Guerin2, Sirine Boussena3
1Hospices Civils de Lyon, Département d'anesthésie, Hôpital Femme Mère Enfant, F - 69500 Bron, France.
Study Objective:
To evaluate the impact of positive end-expiratory pressure (PEEP) with or without pressure support ventilation (PSV) on the lung volume and the ventilation distribution during inhalational induction of anesthesia in children.
Design:
Prospective observational clinical pilot-study.
Setting:
University Children's Hospital of Lyon, France.
Patients:
Children without significant comorbidity (ASA 1 or 2) undergoing planned or unplanned surgery with inhalational induction of anesthesia.
Intervention:
After the beginning of Guedel's stage 3 of anesthesia, several settings were applied for 60 s in the following systematic order: spontaneous breathing when applying a facemask (SB-Mask), then PEEP 4 cmH2O, PSV 4 cmH2O above PEEP 4 cmH2O, and PSV 4 to 7 cmH2O above PEEP 4 cmH2O, at the anesthesiologist's discretion.
Measurements:
Children were monitored using Electrical Impedance Tomography (EIT; Pulmovista 500, Dräger, France). Tidal volume (TV), dorsal fraction of the ventilation, and end-expiratory lung impedance (EELI) were assessed with the ventilator and EIT.
Main Results:
Twenty-two patients were included (20 analyzed), their median [IQR] age was 21 [14-36] months. TV did not significantly differ between the settings. The increase in EELI was greater with PSV (+0.60 [0.48-0.91] arbitrary units) than with PEEP 4 cmH2O alone (+0.39 [0.20-0.06] arbitrary units, p = 0.005), and did not change with increased level of PSV (+0.66 [0.40-1.22] arbitrary units). The dorsal fraction of lung ventilation decreased using PSV, from 56 % [45-63] with SB-mask to 53 % [43-56] with PSV 4cmH2O (p = 0.002) and 47 % [40-55] with PSV 7cmH2O (p = 0.001).
Conclusion:
The ventilator settings used during inhalational induction of anesthesia in children have an impact on lung ventilation. PSV during inhalational induction of anesthesia in children may restore the end-expiratory lung volume independently from the increase in TV.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Inhalational Anesthetics: Overview
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...