Carbon dot-based molecularly imprinted polymer fluorescent sensor for the detection of propranolol in plasma
Jialin Liu1, Ruizhen Li1, Lei Qin2
1Institute of New Carbon Materials, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
Abstract:
Propranolol, a medication used to treat cardiovascular diseases, can be harmful when overdosed and hazardous to ecosystems if released into the environment. Here, a new molecularly imprinted fluorescent sensor was developed from carbon dots through a sol-gel method. Carbon dots served as both the fluorescent signal and the carrier, with propranolol as the template molecule and 3-aminopropyltriethoxysilane as the functional monomer to be grafted on carbon dots' surface. A novel detection method was established for the efficient, rapid, and cost-effective detection of propranolol in human plasma through quantitative analysis by using a fluorescence spectrophotometer and an ultraviolet spectrophotometer. Under the optimal conditions, the detection range of 0.5-4 mg L-1, the detection limit of 0.092 mg L-1, the imprinting factor of 2.42, and the detection response time of 2 min were achieved. The prepared carbon dot-based molecularly imprinted fluorescent sensor was proved to have a wide accurate linear range, low detection limit, and very short response time, and can detect lower analyte concentrations with higher detection accuracy.