Related Experiment Video
Updated: Jun 4, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Computationally efficient collimator-detector response compensation in high energy SPECT using 1D convolutions and
Lucas A Polson1,2, Pedro Esquinas3, Sara Kurkowska2,4
1Department of Physics & Astronomy, University of British Columbia, Vancouver, Canada.
Abstract:
Objective. Modeling of the collimator-detector response (CDR) in single photon emission computed tomography (SPECT) reconstruction enables improved resolution and accuracy, and is thus important for quantitative imaging applications such as dosimetry. The implementation of CDR modeling, however, can become a computational bottleneck when there are substantial components of septal penetration and scatter in the acquired data, since a direct convolution-based approach requires large 2D kernels. This work proposes a 1D convolution and rotation-based CDR model that reduces reconstruction times but maintains consistency with models that employ 2D convolutions. To enable open-source development and use of these models in image reconstruction, we release a SPECTPSFToolbox repository for the PyTomography project on GitHub.Approach. A 1D/rotation-based CDR model was formulated and subsequently fit to Monte Carlo (MC) point source data representative of177Lu,131I, and225Ac imaging. Computation times of (i) the proposed 1D/rotation-based model and (ii) a traditional model that uses 2D convolutions were compared for typical SPECT matrix sizes. Both CDR models were then used in the reconstruction of MC, physical phantom, and patient data; the models were compared by quantifying total counts in hot regions of interest (ROIs) and activity contrast between hot ROIs and background regions.Results. For typical matrix sizes in SPECT reconstruction, application of the 1D/rotation-based model provides a two-fold computational speed-up over the 2D model when running on GPU. Only small differences between the 1D/rotation-based and 2D models (order of 1%) were obtained for count and contrast quantification in select ROIs.Significance. A technique for CDR modeling in SPECT was proposed that (i) significantly speeds up reconstruction times, and (ii) yields nearly identical reconstructions to traditional 2D convolution based CDR techniques. The released toolbox will permit open-source development of similar models for different isotopes and collimators.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Convolution: Math, Graphics, and Discrete Signals
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...