Ultrasound imaging with flexible transducers based on real-time and high-accuracy shape estimation
Xue Gao1, Lihong Huang1, Peng Huang1
1Department of Biomedical Engineering, Fudan University, Shanghai 200438, China.
Abstract:
Ultrasound imaging with flexible transducers requires the knowledge of shape geometry for effective beamforming, which such geometry is variable and often unknown. The conventional iteration-based shape estimation methods estimate transducer shape with high computational expense. Although deep-learning-based methods are introduced to reduce computation time, their low shape estimation accuracy limits the practical applications. In this paper, we propose a novel deep-learning-based approach, called FlexSANet, for shape estimation in ultrasound imaging with flexible transducers, which rapidly achieves precise shape estimation and then reconstructs high-quality images. First, in-phase/quadrature (I/Q) data are demodulated from raw radio frequency (RF) data to provide comprehensive guidance for the estimation task. A sparse processing mechanism is employed to extract crucial channel signals, resulting in sparse I/Q data and reducing the estimation time. Then, a spatial-aware shape estimation network establishes a one-shot mapping between the sparse I/Q data and the flexible probe shape. Finally, the ultrasound image is reconstructed using the delay-and-sum (DAS) beamformer with estimated shape. Massive comparisons on simulation datasets and in vivo datasets demonstrate the superiority of the proposed shape estimation method in rapidly and accurately estimating the transducer shape, leading to real-time and high-quality imaging. The mean absolute error of element position in shape estimation is below 1/8 wavelengths for simulation and in vivo experiments, indicating minimal element position error. The structural similarity between the ultrasound images reconstructed with real and estimated shapes is above 0.84 for simulation experiments and 0.80 for in vivo experiments, demonstrating superior image quality. More significantly, its estimation time on CPU of only 0.12 s promises clinical application potential of flexible ultrasound transducers.
More Related Videos
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...