Related Experiment Video
Updated: Jun 4, 2025

Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
Published on: July 12, 2024
Where's the Remote? Failure to Report Clinical Workflows in Heart Failure Remote Monitoring Studies
Elise L Shalowitz1, Pardeep S Jhund2, Mitchell A Psotka3
1Colorado Center for Personalized Medicine, University of Colorado, Aurora, Colorado.
Background:
Remote patient monitoring (RPM) clinical trials have reported mixed results in improving outcomes for patients with chronic heart failure (HF). The impact of clinical workflows that could impact RPM effectiveness is often overlooked. We sought to characterize workflows and response protocols that could impact outcomes in studies of noninvasive RPM in HF.
Methods:
We reviewed studies (1999-2024) assessing noninvasive RPM interventions for adults with HF. We collected 24 aspects of workflows describing education, physiologic and symptomatic data collection, transmission and review, clinical escalation protocols, and response time. We attempted to perform a meta-analysis to identify associations between workflow components and outcomes of death and hospitalization.
Results:
We identified 63 studies (57.1% randomized controlled, 23.8% pilot/feasibility, 19.1% other) comprising 16,699 subjects. Despite a large number of studies and subjects, workflow reporting was insufficient to perform our intended meta-analysis regarding key workflow components. RPM clinical workflows were diverse in configuration, with high variability in component description ranging from always reported to never reported. Specifics of monitoring devices and related training were well reported as expected based on most trial hypotheses. However, elements of clinical data response such as frequency of data review, clinical escalation criteria, and provider response time were often underreported or not reported at all (48%, 24%, and 97%, respectively), hindering study replication and evidence-based implementation.
Conclusions:
Clinical workflows are poorly described in noninvasive RPM studies, preventing systematic assessment, device comparison, and replication. A standardized approach to reporting HF RPM workflows is vital to evaluate effectiveness and guide evidence-based clinical implementation.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Errors occurring during blood pressure monitoring
Several factors...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation: