Published on: January 20, 2023
Visual detection of pulselessness by carotid artery sonography - A prospective observational study among medical
B Vojnar1, A Holl2, H C Dinges1
1Department of Anesthesiology and Intensive Care Medicine, University Hospital of Giessen and Marburg, Campus Marburg, Marburg, Germany.
Aim:
This cross-sectional study aimed to determine whether medical students with little to no ultrasound experience could correctly distinguish between 'pulsation present' and 'no pulsation present' after a short introductory video on the subject using ultrasound videos of the common carotid artery (CCA).
Methods:
Ultrasound videos (B-mode, M-mode, and Color Doppler) of pulsatile (systolic blood pressure 70-80 mmHg) and non-pulsatile (cardiopulmonary bypass surgery, clamped aorta) CCA were created. These were demonstrated to the medical students for a period of ten seconds - corresponding to the duration of the manual pulse palpation during cardiopulmonary resuscitation (CPR). All participants viewed twenty of these videos in random order on a tablet and were asked to decide whether or not a CCA pulse was present.
Results:
432 participants completed the study in full on 20 cases, enabling a total of 8640 decisions on CCA pulse 'present' or 'not present' to be evaluated. M-mode: in 96 % (1244/1296) of the cases, the participants correctly identified the presence of pulsatile CCA. In the videos without pulsatile CCA, the correct decision 'no pulsation present' was made in 95 % (1231/1296) of the cases. B-mode: the decision 'pulsation present' was made correctly in 69 % (889/1296) of the cases, and in the remaining 31 % (407/1296) the option 'no pulsation present' was incorrectly chosen, although a video with CCA pulsation was shown. In contrast, the correct decision 'no pulsation present' was selected in 99 % of the cases (2142/2160). Color Doppler: CCA pulsation was correctly detected in 99.5 % (1290/1296) of the cases. In the videos without CCA pulsation, 99 % (1281/1296) of the videos were correctly evaluated as 'no pulsation present'.
Conclusion:
Medical students seem to be able to detect the absence of a pulse with a high degree of accuracy using 2D ultrasound of the CCA in a controlled study setting, using different ultrasound modes. The results of this study suggest that a combination of Color Doppler and B-mode may be useful when evaluating the CCA during CPR to answer the question 'pulsation present' or 'no pulsation present'.
Related Concept Videos
Special considerations while measuring pulse
Pulse Assessment Sites
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse
The pulse serves as a clinical...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection