Background:
Unlike on-pump beating coronary artery bypass grafting, off-pump coronary artery bypass grafting (OPCAB) rarely causes intracardiac air embolisms. However, there have been several reports of air embolisms that occurred during OPCAB using a CO2 blower, which is commonly used to facilitate visualization of the anastomotic site. Herein, we describe a rare case of air bubbles detected only in the left ventricle during OPCAB.
Case Presentation:
A 72-year-old man visited our hospital due to a myocardial infarction. Because of diffuse tight stenosis of the coronary artery, urgent OPCAB was performed under median sternotomy. After successful grafting, a significant number of air bubbles were detected in the left ventricle but not in the right side of the heart. To prevent air embolism, the patient was maintained in the Trendelenburg position. The surgery was completed, and no neurological abnormalities were observed during hospitalization.
Conclusions:
Air bubbles entered the left ventricle through a specific route. The use of an excessive flow rate of CO2 blower should be avoided during anastomosis. This case and other similar incidents encourage maintaining vigilant monitoring for air bubbles using transoesophageal echocardiography, even during OPCAB.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests