Related Experiment Video
Updated: Jun 4, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
What is the minimum time interval for reporting of intraoperative core body temperature measurements in pediatric
Clemens Miller1,2, Anselm Bräuer3, Johannes Wieditz1,4
1Department of Anesthesiology, University Medical Center Goettingen, Robert-Koch-Straße 40, 37075, Goettingen, Germany.
Abstract:
Given that perioperative normothermia represents a quality parameter in pediatric anesthesia, numerous studies have been conducted on temperature measurement, albeit with heterogeneous measurement intervals, ranging from 30 s to fifteen minutes. We aimed to determine the minimum time interval for reporting of intraoperative core body temperature across commonly used measurement intervals in children. Data were extracted from the records of 65 children who had participated in another clinical study and analyzed using a quasibinomial mixed linear model. Documented artifacts, like probe dislocations or at the end of anesthesia, were removed. Primary outcome was the respective probability of failing to detect a temperature change of 0.2 °C or more at any one measurement point at 30 s, one minute, two minutes, five minutes, ten minutes, and fifteen minutes, considering an expected probability of less than 5% to be acceptable. Secondary outcomes included the probabilities of failing to detect hypothermia (< 36.0 °C) and hyperthermia (> 38.0 °C). Following the removal of 4,909 exclusions, the remaining 222,366 timestamped measurements (representing just over 60 h of monitoring) were analyzed. The median measurement time was 45 min. The expected probabilities of failing to detect a temperature change of 0.2 °C or more were 0.2% [95%-CI 0.0-0.7], 0.5% [95%-CI 0.0-1.2], 1.5% [95%-CI 0.2-2.6], 4.8% [95%-CI 2.7-6.9], 22.4% [95%-CI 18.3-26.4], and 31.9% [95%-CI 27.3-36.4], respectively. Probabilities for the detection of hyperthermia (n = 9) were lower and omitted for hypothermia due to low prevalence (n = 1). In conclusion, the core body temperature should be reported at intervals of no more than five minutes to ensure the detection of any temperature change in normothermic ranges. Further studies should focus on hypothermic and hyperthermic ranges.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...