Related Experiment Video
Updated: Jun 4, 2025

Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Contrast Agent Pooling in the Descending Aorta Due to Severe Heart Failure
Yosuke Maezawa, Kazuya Nagasaki1, Hiroyuki Kobayashi1
1Mito Kyodo General Hospital, Department of Internal Medicine, University of Tsukuba, Mito, Japan.
Case Presentation:
An 86-year-old female presented to our emergency department with chest pain and orthopnea and was diagnosed with heart failure and ST-elevation myocardial infarction, prompting hospitalization. During hospitalization, she developed a fever. A chest and abdominal contrast-enhanced computed tomography (CT), conducted to investigate the cause of the fever, coincidentally revealed sedimentation of contrast agent in the descending aorta. To differentiate from aortic dissection, we conducted dynamic CT, and it was confirmed that the contrast agent within the aorta decreased over time. On the same day, an echocardiogram revealed a left ventricular ejection fraction of 36% with reduced contractile function, and a stagnant, hazy echo within the descending aorta.
Discussion:
In aortic dissection, the retention of contrast agent in the false lumen of the aorta is a crucial finding for diagnosis. However, we experienced a case where contrast agent accumulated in the descending aorta, caused by low ejection fraction of the left ventricle. Differential diagnosis from aortic dissection may be possible due to the gradual decrease in contrast agent over time. This case is valuable to report given the limited number of previous reports on this phenomenon.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
06:46Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure Drugs: Diuretics
Heart Failure Drugs: Inotropic Agents
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...