Related Experiment Video
Updated: Jun 4, 2025

Fabrication and Operation of an Oxygen Insert for Adherent Cellular Cultures
Published on: January 6, 2010
High pressure excursion in a radial design oxygenator
Ashley Svec1, Tyler Eadie1, Brandon D'Aloiso1
1UPMC Presbyterian Perfusion, 200 Lothrop Street, Pittsburgh, PA 15213, USA.
Abstract:
Oxygenator high-pressure (HPE) is a phenomenon that can occur during cardiopulmonary bypass (CPB) in which the oxygenator inlet pressure increases rapidly, thereby limiting flow. Most perfusionists globally do not use inlet oxygenator pressure monitoring and therefore HPE is not often recognized. HPE may occur for various reasons, and it is not fully understood. Patient factors that put a patient at a higher risk of HPE are increased body surface area, blood type, and hematocrit count. Patient size, blood flow, and pressure drops of the oxygenator incorporated into the circuit can also increase the probability of an HPE occurring. This case study overviews our experience when dealing with an interesting case of HPE and the most up-to-date knowledge on appropriate steps to mitigate the effects on the patient.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
07:38Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Excess Pressure Inside a Drop and a Bubble
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...