Dispersive solid phase extraction of apixaban from human plasma samples prior to capillary electrophoresis
Aysa Abbasalizadeh1, Mohammad Reza Afshar Mogaddam2, Mir Ali Farajzadeh3
1Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran; Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Abstract:
Here, a zirconium-based metal organic framework-dispersive solid phase extraction method was established as an efficient, robust, and accurate approach for quantifying apixabanin human plasma samples prior to capillary electrophoresis with diode array detection. Various types of metal organic frameworks based on UiO-66-NH2 were synthesized by altering modulators and solvents and applied as sorbents in the extraction procedure. Among the tested sorbents, UiO-66-NH2 prepared in dimethylformamide in the presence of acetic acid was found to be the best sorbent in this method for the extraction of apixaban with high extraction efficiency comparable to other types of UiO-66-NH2 metal organic frameworks. The extraction and preconcentration of apixaban were carried out by adding 5 mg of synthesized sorbent to a 5 mL sample solution, followed by vortexing for 3 min. After discarding the supernatant, the adsorbed analyte was eluted from the sorbent surface using 60 µL acetonitrile under vortexing for 2 min. The effective parameters of the offered method were optimized and validated using a one-parameter-at-a- time strategy. The detection and quantification limits of the method were 9.9 and 32 ng mL-1 in plasma and 1.5 and 4.9 ng mL-1 in deionized water, respectively. The method was linear ranging from 4.9 to 1000 ng mL-1 in deionized water and from 32 to 500 ng mL-1 in plasma, respectively. The enrichment factor and extraction recovery values were 44 % and 53 %, respectively. The relative standard deviations were ≤6.2 % for intra- and inter-day precisions. Finally, the proposed method was successfully employed to quantify apixaban in human plasma samples.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Extraction: Advanced Methods
Capillary Electrophoresis: Instrumentation
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrophoresis: Overview
There...