Related Experiment Video
Updated: Jun 4, 2025

Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Validity and reliability of a method to estimate the potential harm of medication errors by considering both the
Rached Al Atassi1, Wing Shun Chan1, Zivile Jurjonaite1
1Department of Life Sciences, University of Bath, Bath, United Kingdom.
Objectives:
To develop a tool to 'risk score' the potential harm of a medication error by estimating the probability of a range of potential consequences, and assess its feasibility, validity, and reliability.
Methods:
The risk score tool described five levels of potential harm developed from an existing risk matrix. Judges estimated the likelihood of harm matching each level, from which a risk score (0-10) was calculated. Thirty judges (doctors, nurses, and pharmacists) used this risk score and the existing Dean and Barber scale to estimate the potential harm of 50 medication errors, 15 with a known outcome. Two weeks later, the judges re-scored ten of the errors. Reliability was investigated using generalizability theory.
Key Findings:
Fifty medication errors were judged in a mean of 49 minutes with ≤0.7% missing data. There were no significant differences in the judges' rating of the realism and ease of use of the two tools. Fifty-nine per cent of judges preferred the risk score tool. For both tools, there was a clear relationship between mean score and known outcomes, with no overlap between outcome categories, confirming discriminative validity. The correlation between scores from both tools (R2 = 0.99) confirmed the concurrent criterion validity of the risk score. For both tools, at least three judges would need to score an error to obtain a generalizability coefficient of ≥0.8 using the mean score as an indicator of potential harm.
Conclusions:
The risk score was feasible, valid, and reliable. Its performance was comparable with, but did not exceed, the Dean and Barber scale.
More Related Videos
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Data Validation
Key parameters for method validation include:
Errors occurring during blood pressure monitoring
Several factors...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...