Related Experiment Video
Updated: Jun 4, 2025

Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
Jet versus vibrating mesh nebulizer for tobramycin aerosol in spontaneously breathing children with tracheostomies: A
Natalie V E Anderson1, William G F Ditcham2, Barry S Clements3
1School of Population Health, Curtin University, Kent St, Bentley WA 6102, Perth, Australia; Perioperative Care Program, Perioperative Medicine Team, Telethon Kids Institute, Northern Entrance, Perth Children's Hospital, 15 Hospital Ave, Nedlands WA 6009, Perth, Australia; Division of Emergency Medicine, Anaesthesia and Pain Medicine, Medical School, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; Institute for Paediatric Perioperative Excellence, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia.
Abstract:
Tracheostomy tubes act as foreign bodies, predisposing the surrounding airway to respiratory infections. Initial treatment for infections is topical - nebulized tobramycin - although guidelines for standardized treatment are lacking. To quantify tobramycin delivery to simulated, tracheostomized children to inform future administration guidelines. A breathing simulator was programmed for volume-controlled ventilation at 6 mL.kg-1, for a 3 kg and a 16 kg child representing under or over 6-yrs, respectively. Nebulized tobramycin doses based on current guidelines for non-tracheostomized children (80 mg, or 300 mg, under and over 6-yrs, respectively) were delivered using standard hospital protocol, collected on filters, and assayed with chromatography to quantify average tobramycin delivered dose from six replicate measurements. The jet nebulizer delivered more tobramycin than the vibrating mesh nebulizer from an 80 mg (ages <6-yrs) dose for both a 3 kg child: 2.1 vs. 0.7 mg (3 mm, p = 0.047) and a 16 kg child: 8.7 vs. 3.5 mg (5 mm size, p = 0.022), 11.4 vs. 8.3 mg (4 mm size, p = 0.2). The jet nebulizer delivered more tobramycin than the vibrating mesh nebulizer from a 300 mg dose for both a 3 kg child: 8.4 vs. 3.7 mg (3 mm, p = 0.00076) and a 16 kg child: 33.2 vs. 25 mg (5 mm, p = 0.2) but not for a 16 kg child: 39.4 vs. 46.5 mg (4 mm, p = 0.18) The low amount and poor distribution of drug delivered warrants consideration and review of dosing regimens for treatment. Future research should investigate improving the efficiency of drug delivery to tracheostomized children and the safety and efficacy of higher-dosage regimens.