Related Experiment Video
Updated: Aug 5, 2026

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Sub-bandage pressure changes in canine hindlimbs after re-application of custom rigid fiberglass splints
Brandon Thibodaux1, Kendra Eginton2, Wanda Gordon-Evans2
1University of Minnesota Veterinary Medical Center, Saint Paul, MN, USA. thibodauxdvm@gmail.com.
Background:
While limited information is available, it is possible that high or low sub-bandage pressures cause injury with external coaptation. Fiberglass casting tape is a common splinting material that is custom made for the first bandage and reused in subsequent bandage changes. The aim of this preliminary study was to determine sub-bandage pressure changes in canine hindlimbs between initial splint placement and replacement of the bandage by a different person. The hypothesis was that there would be a clinically meaningful change in sub-bandage pressures with reapplication of the splint in at least one location. Sub-bandage pressures were measured at five different anatomic locations on each of 11 canine hind limbs with dogs standing and in lateral recumbency after customizing a fiberglass lateral tarsal splint for each dog. A second clinician then reapplied the bandage, reusing the same fiberglass splint. Second bandages failed if there was a change in pressure of 20 mmHg at any location.
Results:
Ten of 11 bandages failed (90%). All but one location failed due to increases in pressure. There were significant changes between lateral recumbency and standing pressures, but there was no consistent pattern of these changes among the dogs.
Conclusion:
There are changes in sub-bandage pressures when the splint is reused in 90% of bandages. In addition, changes in pressure occur unpredictably when transitioning from lateral recumbency to standing. Further study of the relationship of sub-bandage pressures to bandage complications is vital to help establish safe ranges and inform bandaging improvements.
More Related Videos
07:49Application of Consistent Massage-Like Perturbations on Mouse Calves and Monitoring the Resulting Intramuscular Pressure Changes
Published on: September 20, 2019
06:31Automated Gait Analysis to Assess Functional Recovery in Rodents with Peripheral Nerve or Spinal Cord Contusion Injury
Published on: October 6, 2020
Related Concept Videos
Plastic Behavior
Residual Stresses
Residual Stresses in Bending