Edge Chipping Resistance and Flexural Strength of CAD-CAM Ceramics Before and After Thermomechanical Aging
Related Experiment Video
Updated: Jun 4, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Min-Gyu Song1, Kyung-Ho Ko1, Yoon-Hyuk Huh1
1Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
Objectives:
To evaluate the complementary mechanical properties of dental ceramics using edge chipping resistance (Rea) and flexural strength before and after thermomechanical aging.
Material And Methods:
Computer-aided design and computer-aided manufacturing of ceramic materials, including zirconia (ZR), lithium disilicate (LS2), and resin nanoceramics (RNC), were evaluated. Specimens for flexural strength testing were fabricated with dimensions of 3 × 4 × 25 mm, with 30 specimens per group. For the edge chipping test (ECT), specimens were fabricated with dimensions of 3 × 4 × 12 mm, with 48 specimens per group. Half of the specimens for both tests were subjected to thermomechanical aging for 200,000 cycles at 50 N. A Weibull analysis was performed to determine flexural strength. Fractographic analysis was performed before and after thermomechanical aging during the ECT. X-ray diffractometry (XRD) was performed on the ZR specimens before and after thermomechanical aging. Flexural strength was analyzed using a two-way repeated analysis of variance (ANOVA) with a t-test, and Rea was analyzed using Pearson correlation and a two-way repeated ANOVA.
Results:
The flexural strength and Rea differed according to the material (p = 0.001), whereas they were similar before and after thermomechanical aging (p > 0.05). The Weibull modulus of the flexural strength decreased after thermomechanical aging. In the fractographic analysis of the ECT, more than two fracture origins were identified after thermomechanical aging. The XRD analysis of ZR showed an increased monoclinic phase after thermomechanical aging.
Conclusion:
All the materials met the ISO 6872 standards for bending test. However, LS2 and RNC show low edge chipping resistance within the range of the occlusal force. The thermomechanical aging did not significantly alter the mechanical properties of the materials. However, the Weibull coefficients of the flexural strength decreased, and an additional origin of fracture appeared after thermomechanical aging.
Significance:
Flexural strength and Rea differed depending on the material used. The probability of the material fracture increased after thermomechanical aging. To understand ceramic fractures, two mechanical tests and thermomechanical aging must be performed together.
More Related Videos
03:37Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
Related Concept Videos
Brick Durability, Strength, and Appearance
Fatigue
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Mortar Properties