Related Experiment Video
Updated: Jun 4, 2025

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
CustOmized versus standard fundal-height measuREments for the detection of small-for-gestational age fetuses in
Farhat Ul Ain Ahmed1, Sharoon Hanook2, Fatima Ismail1
1Fatima Memorial Hospital, NUR International University, Lahore, Pakistan.
Objective:
To compare the proportion of small-for-gestational age (SGA) infants detected by routine care versus a growth assessment protocol using customized fundal-height charts in low-risk pregnancies of a developing country.
Methods:
An open label randomized controlled trial was conducted at the Fatima Memorial Hospital (NUR International University, Pakistan). Low-risk pregnant women were randomly allocated to routine care (Mcdonald's rule for fundal height measurements followed by referral for scan with discrepancy of 3 cm from gestational age and a contingency third trimester scan) or the growth assessment protocol (GAP) developed by the Perinatal Institute (UK), which consists of the use of gestation-related optimal weight (GROW) customized charts, alongside management protocols for suspected SGA fetuses, audit tools and training. The primary prespecified outcome was the detection of SGA (defined as a birthweight <10th centile).
Results:
Of the 2535 eligible women, 1884 (74%) were randomized (942 to standard care and 942 to GAP). After loss-to-follow-up, 1755 women were analyzed (874 in the standard measurement group and 881 in the GAP group). The detection rate of SGA infants was higher in the GAP group (83.2% [95% CI: 74.4%-89.9%] vs. 29% [95% CI: 20.4%-38.9%], P < 0.001), at the cost of an increased false positive rate (10.4% [95% CI: 8.3%-12.7%] vs. 1.4% [95% CI: 0.7%-2.5%], P < 0.001). The diagnostic odds ratio (positive likelihood ratio/negative likelihood ratio) was 42.6 (95% CI: 24.1-75.4) in the GAP group and 28.3 (95% CI:13.6-59.1) in the standard care group.
Conclusion:
In low-risk pregnant women of a developing country, a growth assessment protocol based on customized fundal-height charts is superior to standard measurements for the antenatal detection of SGA in newborns.
Related Concept Videos
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
One-Way ANOVA: Unequal Sample Sizes

