Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Hip Arthroscopy and Proximal Femoral Derotation Osteotomy for Femoral Anteversion: "The HAM Technique".

Arthroscopy techniques·2025
Same author

Bone Marrow Aspirate Concentrate Harvest and Delivery With a Neonatal Nasogastric Tube: A Simple Technique in Hip Arthroscopy.

Arthroscopy techniques·2025
Same author

Lateral Meniscus Allograft Transplantation With Lateral Meniscotibial Ligament Reconstruction.

Arthroscopy techniques·2025
Same author

Injection of the Hip With Hyaluronic Acid Under Distraction Plus Neurectomy of the Femoral and Obturator Nerve.

Arthroscopy techniques·2024
Same author

Quantitative cotyloid fossa thickness and proximity to obturator neurovascular bundle: implications for arthroscopic ligamentum teres reconstruction.

Journal of hip preservation surgery·2024
Same author

Hip Arthroscopy in Adolescents Through an Extra-Capsular Approach.

Arthroscopy techniques·2023

Related Experiment Video

Updated: Jun 4, 2025

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
06:16

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy

Published on: May 1, 2020

5.5K

Postless Hip Arthroscopy for Labrum Reconstruction and Labrum Augmentation.

Antonio Porthos Salas1, José Luis Pérez Lara-Albisua2, David S Taffinder-Villarreal2

  • 1Hip Arthroscopy Mexico, San Pedro Garza García, México.

Arthroscopy Techniques
|December 23, 2024
PubMed
Summary

This study introduces a novel postless hip arthroscopy technique for labral reconstruction and augmentation. This method aims to reduce iatrogenic complications associated with traditional hip distraction methods.

More Related Videos

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
09:51

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve

Published on: September 7, 2022

2.5K
Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
08:40

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs

Published on: April 19, 2024

2.0K

Related Experiment Videos

Last Updated: Jun 4, 2025

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
06:16

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy

Published on: May 1, 2020

5.5K
The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
09:51

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve

Published on: September 7, 2022

2.5K
Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
08:40

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs

Published on: April 19, 2024

2.0K

Area of Science:

  • Orthopedic Surgery
  • Arthroscopy
  • Hip Joint

Background:

  • Hip arthroscopy is an effective surgical treatment with good outcomes and low complication rates.
  • Hip distraction is essential for accessing the hip joint for labral repair or reconstruction.
  • Iatrogenic complications related to hip distraction have been documented.

Purpose of the Study:

  • To present a modified postless hip arthroscopy technique for labral augmentation and reconstruction.
  • To address the lack of described postless techniques for comprehensive labral reconstruction.

Main Methods:

  • A modified postless hip arthroscopy technique is described.
  • The technique is based on Dr. Brian J. White's 'front-to-back' hip arthroscopic labral reconstruction method.
  • It allows for labral augmentation and reconstruction without the use of a post.

Main Results:

  • The study presents a novel approach to hip labral reconstruction.
  • This technique facilitates postless hip arthroscopy for labral augmentation and reconstruction.

Conclusions:

  • The described modified technique offers a postless approach for hip labral augmentation and reconstruction.
  • This technique may help mitigate iatrogenic complications associated with traditional hip distraction.