Related Experiment Video
Updated: Jul 12, 2026

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
A nomogram model to predict non-retrieval of short-term retrievable inferior vena cava filters
Lihao Qin1, Xiaocheng Gu1, Caifang Ni2
1Department of Interventional and Vascular Surgery, The Affiliated Changzhou Second People's Hospital of Nanjing Medical University, Changzhou, China.
Objective:
To develop and validate a nomogram for predicting non-retrieval of the short-term retrievable inferior vena cava (IVC) filters.
Methods:
In this study, univariate and multivariate logistic regression analyses were performed to identify predictive factors of short-term retrievable filter (Aegisy or OptEase) non-retrieval, and a nomogram was then established based on these factors. The nomogram was created based on data from a training cohort and validated based on data from a validation cohort. The predictive value of the nomogram was estimated using area under the curve (AUC) and calibration curve analysis (Hosmer-Lemeshow test).
Results:
A total of 1,321 patients who had undergone placement of short-term retrievable filters (Aegisy or OptEase) were included in the analysis. The overall retrieval rate was 68.7%. Age, proximal and distal deep vein thrombosis (DVT) vs. distal DVT, active cancer, history of long-term immobilization, VTE was detected in the intensive care unit, active/recurrent bleeding, IVC thrombosis, and history of venous thromboembolism were independent predictive risk factors for non-retrieval of filters. Interventional therapy for DVT, acute fracture, and interval of ≥14 days between filter placement and patient discharge were independent protective factors for non-retrieval of filters. The nomogram based on these factors demonstrated good ability to predict the non-retrieval of filters (training cohort AUC = 0.870; validation cohort AUC = 0.813.
Conclusion:
This nomogram demonstrated strong predictive accuracy and discrimination capability. This model may help clinicians identify patients who are not candidates for short-term retrievable filter placement and help clinicians make timely, individualized decisions in filter choice strategies.
More Related Videos
Related Concept Videos
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Venous Thrombosis III: Interprofessional Care
Hemodialysis I: Introduction