Related Experiment Video
Updated: Jun 4, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Coupled waveform patterns in the arterial and venous fontan circulation are related to parameters of pulmonary,
Margaret R Ferrari1, Michal Schäfer2, Kendall S Hunter1
1Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA.
Abstract:
The lack of a sub-pulmonary ventricle in patients with a Fontan circulation contributes to circulatory decline, largely related to increased central venous pressure. Our group has determined that single-site waveform analysis correlates with clinical features of Fontan patients. The goal of this study was to determine if multi-site waveform analysis yielded additional associations with functional status or cardiac performance. Patients with a Fontan circulation (N = 95) that underwent free-breathing cardiac MRI were included in this study. Volumetric flow rate curves were sampled in the ascending aorta, superior vena cava, inferior vena cava and left pulmonary artery. Flow curves were interpolated to equal temporal phases and were then used to create three data matrices of arterial and venous waveforms. Principal component analysis was performed on each matrix and principal components that accounted for >10% variance were correlated to traditional clinical indices. Results indicate correlation of inferior and superior vena cava waveform patterns to parameters of pulmonary (RV/TLC %, lowest SaO2%), lymphatic (cystatin-c, BUN, alkaline phosphatase) and to ventricular function (CI, EF, EDVi, ESVi and VVCR). This study demonstrates that coupled waveform analysis of arterial and venous vessels relays additional information about Fontan patient status.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
10:02Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Published on: April 29, 2011
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Overview of Systemic and Pulmonary Circulation
The oxygenated blood is sent...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Blood Flow
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...