Related Experiment Video
Updated: Jun 4, 2025

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Comparison of the Performance of ICP-MS, CV-ICP-OES, and TDA AAS in Determining Mercury in Marine Sediment Samples
Carolina S Provete1, Bruna M Dalfior1, Rafael Mantovaneli1
1Laboratory of Atomic Spectrometry (LEA), Chemistry Department, Federal University of Espírito Santo, Vitória, Espírito Santo 29075-910, Brazil.
Abstract:
Mercury (Hg) determination in marine sediment is an analytical challenge due to the toxicity of this element even at low concentrations (up to 130 μg kg-1 in marine sediments) and complex matrices. Therefore, it is necessary to use analytical techniques that have high sensitivity, selectivity, and low limits of quantification (LoQ). In this study, two methods that require sample treatment and one method with direct sampling were studied. The techniques studied were inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma optical emission spectrometry with cold vapor generation (CV-ICP-OES), and atomic absorption spectrometry with thermodecomposition and amalgamation (TDA AAS) for Hg determination in marine sediment samples. Since ICP-MS has more studies in the literature, optimization with design of experiments was developed for CV-ICP-OES and TDA AAS. Although it was found to have low levels of instrumental LoQ for all three techniques, differences were found once the method LoQ was calculated. The calculation for method LoQ considers all analytical procedures executed, including sample treatment, which provides a 100-fold dilution for ICP-MS and CV-ICP-OES. The method LoQ obtained were 1.9, 165, and 0.35 μg kg-1 for ICP-MS, CV-ICP-OES, and TDA AAS, respectively. Comparing marine sediment sample analyses, Hg concentrations had no statistical difference when determined by ICP-MS and TDA AAS. It was not possible to determine Hg in marine sediment samples by CV-ICP-OES due to the high method LoQ obtained (165 μg kg-1). Although ICP-MS has the advantage of being a multielemental technique, it is high-value equipment and needs a large volume of argon, which has a high cost in the market, and it requires sample treatment. On the other hand, TDA AAS-based spectrometer DMA-80 performs direct sampling, avoiding the pretreatment stage, and has a relatively lower cost, both in terms of initial investment and maintenance, while maintaining the high sensitivity, accuracy, and precision required for Hg determination on marine sediment samples.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...