Related Experiment Video
Updated: Jun 23, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Charging and Discharging of Poly(m-aminophenylboronic Acid) Doped with Phytic Acid for Enzyme-Free Real-Time
Ryujiro Kishi1, Shoichi Nishitani1, Hiroyuki Kudo2
1Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
Abstract:
In this study, we realized a real-time and enzyme-free measurement of lactate in sweat in the same way as an enzyme-based amperometric method. A conductive polymer, which is based on polyaniline (PANI), was strongly coated on a glassy carbon electrode as a poly m-aminophenylboronic acid (PANI-PBA) membrane by drop-casting, which is a convenient method, owing to adhesive phytic acid (PA) molecules with negative charges included as a dopant. This polymer membrane had a functional structure with PBA in the PANI main chain, which expectedly induced electrical charges upon diol binding to lactate, owing to the formation of deprotonated boronate esters with negative charges. This indicates that PBA served as the self-dopant and as the site of binding to lactate. On the basis of the fundamental electrochemical characteristics such as the membrane resistance, the change in the current density of the PA-doped PANI-PBA electrode was quantitatively monitored with the change in lactate concentration from 1 to 300 mM under acidic conditions in real time, considering pH and interfering substances in sweat. Moreover, the sweat lactate concentration was determined to be ca. 60 mM using the PA-doped PANI-PBA electrode in a microfluidic system in measurements using sweat samples collected during exercise load. A change in current density induced a change in the density of charges in the capacitive PA-doped PANI-PBA membrane. This means that the detection mechanism for the change in the lactate concentration in sweat was based on repeated charging and discharging in the PA-doped PANI-PBA electrode.
More Related Videos
06:18Mapping Metabolism: Monitoring Lactate Dehydrogenase Activity Directly in Tissue
Published on: June 21, 2018
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Buffers
Introduction to Electrolytes
Role of Sodium
One...
Potentiometry: Membrane Electrodes
Acid-Base Balance
When the pH of arterial blood rises above 7.45, it results in a condition called alkalosis. Conversely, a drop below 7.35 leads to...
Renal Regulation of Acid-Base Balance
In the kidneys, cells within the proximal convoluted tubules (PCT) and the collecting ducts secrete hydrogen ions (H+) into the tubular fluid. Specifically, in the PCT, Na+/H+ antiporters secrete H+ while reabsorbing Na+.
However, the intercalated cells in...
Buffers: Overview