Related Experiment Video
Updated: May 8, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Diagnostic accuracy of case-identification algorithms for heart failure in the general population using routinely
Anita Andreano1, Vito Lepore2, Pietro Magnoni3
1SC Unità Di Epidemiologia, Agenzia Di Tutela Della Salute Della Città Metropolitana Di Milano, Via Conca del Naviglio 45, Milan, 20123, Italy.
Background:
Heart failure (HF), affecting 1-4% of adults in industrialized countries, is a major public health priority. Several algorithms based on administrative health data (HAD) have been developed to detect patients with HF in a timely and inexpensive manner, in order to perform real-world studies at the population level. However, their reported diagnostic accuracy is highly variable.
Objective:
To assess the diagnostic accuracy of validated HAD-based algorithms for detecting HF, compared to clinical diagnosis, and to investigate causes of heterogeneity.
Methods:
We included all diagnostic accuracy studies that utilized HAD for the diagnosis of congestive HF in the general adult population, using clinical examination or chart review as the reference standard. A systematic search of MEDLINE (1946-2023) and Embase (1947-2023) was conducted, without restrictions. The QUADAS-2 tool was employed to assess the risk of bias and concerns regarding applicability. Due to low-quality issues of the primary studies, associated with both the index test and the reference standard definition and conduct, and to the high level of clinical heterogeneity, a quantitative synthesis was not performed. Measures of diagnostic accuracy of the included algorithms were summarized narratively and presented graphically, by population subgroups.
Results:
We included 24 studies (161,524 patients) and extracted 36 algorithms. Algorithm selection was based on type of administrative data and DOR. Six studies (103,018 patients, 14 algorithms) were performed in the general outpatient population, with sensitivities ranging from 24.8 to 97.3% and specificities ranging from 35.6 to 99.5%. Eight studies (14,957 patients, 10 algorithms) included hospitalized patients with sensitivities ranging from 29.0 to 96.0% and specificities ranging from 65.8 to 99.2%. The remaining studies included subgroups of the general population or hospitalized patients with cardiologic conditions and were analyzed separately. Fourteen studies had one or more domains at high risk of bias, and there were concerns regarding applicability in 9 studies.
Discussion:
The considerable percentage of studies with a high risk of bias, together with the high clinical heterogeneity among different studies, did not allow to generate a pooled estimate of diagnostic accuracy for HAD-based algorithms to be used in an unselected general adult population.
Systematic Review Registration:
PROSPERO CRD42023487565.
More Related Videos
07:51Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
Published on: September 26, 2018
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Genome-wide Association Studies-GWAS
GWAS does not require the identification of the target gene involved in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Pathophysiology of Heart Failure