Related Experiment Video
Updated: May 12, 2026

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Impact of the Individual Operator Experience and Learning Curve of a Novel Size Adjustable Cryoballoon
Yosuke Hayashi1, Shinsuke Miyazaki2, Junichi Nitta1
1Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Background:
Cryoballoon ablation is less operator-dependent than radiofrequency ablation. Recently, size-adjustable cryoballoons (SA-CBs) have become available. We sought to analyze the individual baseline operator experience's impact on procedural results.
Methods:
This multicenter observational study included atrial fibrillation (AF) patients who underwent pulmonary vein (PV) isolation using SA-CBs capable of 28-mm or 31-mm balloon sizes. Experienced (E-group) or less experienced (LE-group) operators were defined as experiencing > 100 or ≤ 100 cryoballoon procedures, respectively.
Results:
Among 510 patients (67 ± 11 years, 355 men, 325 paroxysmal AF [PAF]) who underwent an SA-CB ablation, 240 and 270 were in the E-group and LE-group, respectively. All cryoballoon parameters were similar between the groups, except for a significantly higher 31-mm balloon isolation rate in the E-group than LE-group, especially for right superior PVs. Cryoballoon-related phrenic nerve injury occurred in 34 (6.7%) patients and tended to be higher in the LE-group than E-group (8.1% vs. 5.0%, p = 0.16). The AF freedom was comparable between the groups for both PAF and non-PAF patients. A total of 36(7.1%) patients underwent re-do procedures at 5.2 ± 2.6 months post-index procedure. The PV reconnection rate was significantly higher in the LE-group than E-group (27.1% vs. 8.9%, p < 0.01), and this trend was more pronounced for right PVs than left PVs.
Conclusions:
In AF ablation using SA-CBs, the overall procedural efficacy and safety were comparable between the E-group and LE-group. However, 100 CB procedures seemed to still be in the middle of a learning curve for selecting the balloon size and balloon position, especially for right PVs.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
09:51Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators
Published on: March 21, 2018
Related Concept Videos
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Factors Affecting Body Temperature
Factors may include:
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...